ST-02
crankcase flange, dome light, single 5 MP view · Auto mode · last 8 hours
Where the time goes
The latency budget for the most recent part, stacked against the physical deadline — the last moment this part could still be diverted
- Image transfer
- Quality gate
- Pre-processing
- Inference
- Policy & PLC write
- PLC scan & ack
Part ST-02-000000000400, trigger 400. Image transfer usually dominates on 1 GigE at 5 MP and above — camera-side region of interest and a faster link come before anything is done to the model.
Latency distribution
Every part in the window. The shape of the tail is the point: a P95 target alone lets one part in twenty be late
Digital I/O handshake
The six wires to the PLC for one part. The heartbeat underneath is the signal the PLC acts on the absence of
Health
What the station is reporting about itself
- Bundle
- 2026.09.21-141131
- Recipe
- R-DEMO-01
- Self-test
- Reproduced
- Mode
- Auto
Cameras
| Serial | Frames | Dropped | Timeouts | Mean level |
|---|---|---|---|---|
| SIM-0001 | 396 | 0 | 4 | 88.0 |
Why parts were held
The coded reason on every non-passing decision
| Code | Reason | Parts |
|---|---|---|
| 201 | Known defect detected with high confidence. | 59 |
| 204 | Classifier and anomaly model disagree. | 17 |
| 103 | Reflection covers part of the inspected area. | 12 |
| 202 | Result is not confident enough to decide automatically. | 6 |
| 301 | Part does not look like anything the model has seen. | 5 |
| 205 | Mark found but smaller than the size limit for its class. | 5 |
| 109 | Camera did not deliver a frame in time. | 4 |
Defects found
No defects recorded in this window.
Live decisions
- 14:12:39PassST-02-000000000400Part passed inspection.73 ms
- 14:12:39PassST-02-000000000399Part passed inspection.67 ms
- 14:12:39PassST-02-000000000398Part passed inspection.62 ms
- 14:12:38PassST-02-000000000397Part passed inspection.67 ms
- 14:12:38PassST-02-000000000396Part passed inspection.66 ms
- 14:12:38PassST-02-000000000395Part passed inspection.79 ms
- 14:12:38PassST-02-000000000394Part passed inspection.75 ms
- 14:12:38PassST-02-000000000393Part passed inspection.64 ms
- 14:12:38PassST-02-000000000392Part passed inspection.61 ms
- 14:12:38PassST-02-000000000391Part passed inspection.69 ms
- 14:12:38PassST-02-000000000390Part passed inspection.66 ms
- 14:12:38PassST-02-000000000389Part passed inspection.58 ms
- 14:12:38PassST-02-000000000388Part passed inspection.67 ms
- 14:12:38RejectST-02-000000000387Dent71 ms
- 14:12:38PassST-02-000000000386Part passed inspection.60 ms
- 14:12:37PassST-02-000000000385Part passed inspection.57 ms
- 14:12:37RejectST-02-000000000384Burr62 ms
- 14:12:37PassST-02-000000000383Part passed inspection.62 ms
- 14:12:37PassST-02-000000000382Part passed inspection.58 ms
- 14:12:37PassST-02-000000000381Part passed inspection.61 ms
- 14:12:37RejectST-02-000000000380Burr82 ms
- 14:12:37PassST-02-000000000379Part passed inspection.56 ms
- 14:12:37PassST-02-000000000378Part passed inspection.58 ms
- 14:12:37PassST-02-000000000377Part passed inspection.66 ms
- 14:12:37PassST-02-000000000376Part passed inspection.67 ms
- 14:12:37PassST-02-000000000375Part passed inspection.65 ms
- 14:12:37PassST-02-000000000374Part passed inspection.71 ms
- 14:12:37RejectST-02-000000000373Burr75 ms
- 14:12:36PassST-02-000000000372Part passed inspection.53 ms
- 14:12:36PassST-02-000000000371Part passed inspection.53 ms
Average time per stage
Across every part in the window — the shift report's version of the budget
- Image transfer
- Quality gate
- Pre-processing
- Inference
- Policy & PLC write
- PLC scan & ack